For use with gas and
liquids. Precision-machined TEFLON® PTFE-tipped plungers Replaceable plungers |
Volume | 10 µl | 25 µl | 50 µl | 100 µl | 250 µl | 500 µl | |
Model | 1701 | 1702 | 1705 | 1710 | 1725 | 1750 | |
Gauge** | 26s | 22s | 22s | 22s | 22s | 22 | |
SN
(Cemented Needle) point style 2 |
80000 | 80200 | 80900 | 81000 | 81100 | 812171) | |
SN
(Cemented Needle) point style 3 |
80075 | 80275 | 80975 | 81075 | 81175 | 812161) | |
SN
(Cemented Needle) point style 5 |
80039 | 80239 | 80939 | 81039 | 81139 | 812431) | |
SN (Cemented Needle) Specify needle gauge, length, point style, and whether electro-tapered | 80008 | 80208 | 80908 | 81008 | 81108. | 812141) | |
RN (Removable Needle) point style 2 | 80030 | 80230 | 80930 | 81030 | 81130 | 81230 | |
RN (Removable Needle) point style 3 | 800652) | 80265 | 80965 | 81065 | 811652) | 81265 | |
RN (Removable Needle) Syringe Needle not included | 7653-01 | 7654-01 | 7655-01 | 7656-01 | 7657-01 | 7658-01 | |
LT (Luer Tip) Needle not included | 80001 | 80201 | 80901 | 81001 | 81101 | 81201 | |
SampIeLock Syringe point style 2 | 80956 | 81056 | 81156 | 81256 | |||
TLL (TEFLON® Luer Lock) w/o slots Needle not included | 80920 | 81020 | 81120 | 81220 | |||
TLL with slots Needle not included | 80927 | 81027 | 81127 | 81227 | |||
TLLX, TLL with stop Needle not included | 80222 | 80922 | 81022 | 81122 | 81222 | ||
TLL-XL Needle not included |
201790 | 201797 | 201802 | 201807 | |||
TLLXB, TLL with stop & backbushing Needle not included | 80223 | 80947 | 81047 | 81147 | 81247 | ||
DX,
Diluter with stop Needle not included |
80226 | 80926 | 81026 | 81126 | 81226 | ||
AD,
AccuDil® with stop Needle not included |
201000 | 201050 | 201100 | 201150 | |||
DAD,
Diluter AccuDil® with stop Needle not included |
201500 | 201550 | 201600 | 201650 | |||
CX,
CHEM with stop Needle not included |
80062 | 80262 | 80962 | 81062 | 81162 | 81262 | |
C-XP Needle not included |
201720 | 201730 | 201740 | 201750 | |||
Digital Syringe Base unit plus syringe of your choice | Add
the prefix "DS" to the beginning of the syringe's part number. (Digital Syringes are automatically calibrated prior to shipment. Base unit not sold separately) |
||||||
PB600
Repeating Dispenser Syringe not included |
83700 | 83700 | 83700 | 83700 | 83700 | 83700 | |
Reproducibility
(Chaney) Adapter Syringe not included |
14700 | 14725 | 14725 | 14725 | 14725 | 14725 | |
Syringe Guide Syringe not included |
14806 | 14906 | 14906 | 14906 | 14906 | 14906 |
Volume | 10 µl | 25 µl | 50 µl | 100 µl | 250 µl | 500 µl | |
Description | Model | 1701 | 1702 | 1705 | 1710 | 1725 | 1750 |
2. RN Nut | 30902 | 30902 | 30902 | 30902 | 30902 | 30902 | |
Needles | siehe Nadelseite |