Life Science Syringes

Operating Parameters:
Maximum temperature is 50° C
Maximum test pressure is 6 bar

Threaded Plunger Syringes

25 µl
For applications requiring extremely precise plunger movement or minute fluid manipulation
Dispense from 0.33 to 13.23 µl per plunger revolution
Luer Tip (LT) syringe terminations for easy connection of Kel-F® hub stainless steel needles; Kel-F® hub TEFLON® tubing; and 6.4 mm O.D. x 3.2 mm I.D. Tygon® or rubber tubing

Ordering Information

Artikelnummer Model Volume Description Volume per Rotation
80266 1702 TPLT 25 µl Sleeve type 0,33 µl
81041 1710 TPLT 100 µl Sleeve type 1,32 µl
81242 1750 TPLT 500 µl Plunger type 5,29 µl
81341 1001 TPLT 1,0 ml Plunger type 13,23 µl

Multi-Channel Gel Loading Syringes

10 µl
Designed for multiplex DNA sequencing methodologies
Rapidly transfer 8 samples to sequencing gels, MICROTITER® plates, or nylon membranes
Accurately dispense from 0.2 to 10 µl of sample per syringe simultaneously
9 mm needle spacing and three needle diameters optimize sample transfers
Adjustable volume stops allow faster, more accurate reloading and excellent repoducibility
Hamilton Multikanal Gel Spritze

Ordering Information

  Volume 10 µl 10 µl 10 µl
Gauge Special Sleeved 26.5s 27
For best results, select the needle design which most closely matches your gel  thickness Use For loading samples into or on 0.2 mm or thicker gel casting plates For loading samples on
0.3 mm or thicker gel
casting plates
For loading samples on
0.4 mm or thicker gel
casting plates
8-Channel Gel Loading syringe point style 3 (**/25/3) 84511 84503/ 854,10/Stck. 84502
Single Channel DNA Syringe point style 3 (**/25/3) 80081 84505/ 58,70/Stck. 84504

Replacement Parts

  Volume 10 µl 10 µl 10 µl
Description Gauge Special 26.5s 27
1. Syringe(1/pk)   80023 80022 80021
2. Plunger Assembly(1/pk)   15948 15948 15948
3. Glass Barrel (1/pk)   10398 10396 10395
4. Stop Collar Kit1)   1993-01 1993-01 1993-01
1) Stop Collar Kit includes Stop Collars (2 each), Set Screws (2 each), and hex wrench (1 each)

Adjustable Gel Loading Syringes (AGLS)

Hamilton Gel Ladungs Spritze 10 µl Simplify and speed sample loading of 96-lane gels on ABI PRISM® 377 DNA sequencing instrument
Rapidly transfer 8 samples at a time from a microwell plate with 9 mm spacing to 96-lane gel with 10.8 mm spacing
Removable needles for complete interchangeability of needle designs, and clogged or damaged needles
Accurately dispense from 0.2 to 10 µl

Ordering Information

For best results, select the needle design which most closely matches your gel  thickness Volume 10 µl
Gauge Special Sleeved
Use For loading samples into or on 0.2 mm or thicker gel casting plates
8-Channel Gel Loading syringe point style 3 (**/25/3) 84611

Replacement Parts

  Volume 10 µl 10 µl
Description Gauge Special 26.5s
1. AGLS Needle (4/pk)   78633 78631
2. Plunger Assembly(1/pk)   15948 15948
4. Stop Collar Kit2)   1993-01 1993-01

 2) Stop Collar Kit includes Stop Collars (2 each), Set Screws (2 each), and hex wrench (1 each)

HLA (Terasaki) Dispenser

25 µl - 500 µl Accurately dispense six samples simultaneously up to 50 times with the press of a lever
Designed for rapid filling of 60 well HLA trays with 6.35 mm well spacing
Removable needles (RN)
Plunger assemblies and glass barrels are replaceable
Hamilton HLA Dispenser

Ordering Information

Description Syringe Model 1702 1705 1710 1725 1750
Volume 25 µl 50 µl 100 µl 250 µl 500 µl
µl per Dispense 0,5 µl 1 µl 2 µl 5 µl 10 µl
HLA Dispenser Part Number   201900 201910 201920 201930 201940

Replacement Parts

Description Syringe Model 1702 1705 1710 1725 1750
Volume 25 µl 50 µl 100 µl 250 µl 500 µl
1. Plunger Assembly(1/pk)   1122-01 1162-01 1162-02 1162-03 1169-01
Needles1) siehe Nadelseite